Please use this identifier to cite or link to this item:
http://hdl.handle.net/2248/2955
Title: | New mounting for x-ray and extreme ultra-violet concave holographic grating |
Authors: | Reddy, G. P Singh, M |
Keywords: | Instrumentation and Measurement Optics Quantum Optics Lasers |
Issue Date: | Apr-1988 |
Publisher: | Institute of Physics |
Citation: | Journal of Optics-Nouvelle Revue D Optique, Vol. 19, No. 2, pp. 77 - 82 |
Abstract: | An entirely new mounting for concave holographic gratings for X-ray and the extreme ultraviolet (EUV) has been proposed and its properties have been investigated theoretically. Design parameters for recording a holographic concave grating for minimum spectral image aberrations have been calculated. It is found that this mounting is very suitable. |
URI: | http://hdl.handle.net/2248/2955 |
ISSN: | 0150-536X |
Appears in Collections: | IIAP Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
New mounting for X-ray and extreme ultraviolet concave | 353.67 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.