http://hdl.handle.net/2248/2955| Title: | New mounting for x-ray and extreme ultra-violet concave holographic grating |
| Authors: | Reddy, G. P Singh, M |
| Keywords: | Instrumentation and Measurement Optics Quantum Optics Lasers |
| Issue Date: | Apr-1988 |
| Publisher: | Institute of Physics |
| Citation: | Journal of Optics-Nouvelle Revue D Optique, Vol. 19, No. 2, pp. 77 - 82 |
| Abstract: | An entirely new mounting for concave holographic gratings for X-ray and the extreme ultraviolet (EUV) has been proposed and its properties have been investigated theoretically. Design parameters for recording a holographic concave grating for minimum spectral image aberrations have been calculated. It is found that this mounting is very suitable. |
| URI: | http://hdl.handle.net/2248/2955 |
| ISSN: | 0150-536X |
| Appears in Collections: | IIAP Publications |