IIA Institutional Repository

Estimation of asymmetries in point spread function for the echelle spectrograph operating at Vainu Bappu Telescope for high precision radial velocity studies

Show simple item record

dc.contributor.author Sireesha, C
dc.contributor.author Banyal, R. K
dc.contributor.author Sriram, S
dc.date.accessioned 2020-11-19T14:03:06Z
dc.date.available 2020-11-19T14:03:06Z
dc.date.issued 2018-07
dc.identifier.citation Proceedings of the SPIE, Vol. 10702, 1070275-1- 1070275-10 en_US
dc.identifier.issn 1996-756X
dc.identifier.uri http://prints.iiap.res.in/handle/2248/7294
dc.description Restricted Access © SPIE--The International Society for Optical Engineering https://doi.org/10.1117/12.2312508 en_US
dc.description.abstract Precision in the Radial Velocity (RV) measurements depends upon the efficiency of the technique to remove instrumental artifacts from stellar measurements. Iodine absorption cell technique is being implemented for high precision studies with the Echelle spectrograph operating at Vainu Bappu Telescope (VBT), Kavalur, India. Since the star spectrum is convolved with the PSF of the spectrograph, the asymmetries in the PSF are imposed on the stellar spectral lines. The fiber fed Echelle spectrograph is a general purpose instrument, designed for high resolution (R = 60,000) spectroscopic observations. The asymmetries in the Point Spread Function (PSF) arise due to the off-axis launching of the stellar beam into the collimator and vignetting across the field. Apart from this, due to usage constraints, the grating of the spectrograph is a movable component. The impact on the Doppler shift calculations due to the movable components in the spectrograph is to be estimated. For upgrading the spectrograph for precision studies, the component level sensitivity for RV is to be analyzed. Thus, instrument design asymmetries and component induced PSF variations are analyzed to estimate the limitations of the spectrograph for precision studies. We have developed Zemax based optical design of the spectrograph to estimate the PSF variations and design limitations on the RV studies. Here, we present a model developed in Zemax and a preliminary analysis on RV sensitivity and the PSF asymmetries of the spectrograph. These instrument variations are to be taken as input during RV data reduction for precision measurements. en_US
dc.language.iso en en_US
dc.publisher SPIE--The International Society for Optical Engineering en_US
dc.subject Echelle Spectrograph en_US
dc.subject Asymmetries in PSF en_US
dc.subject Zemax en_US
dc.subject Iodine absorption cell en_US
dc.subject Radial Velocity en_US
dc.subject Vainu Bappu Telescope en_US
dc.title Estimation of asymmetries in point spread function for the echelle spectrograph operating at Vainu Bappu Telescope for high precision radial velocity studies en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account