IIA Institutional Repository

The estimation of the instrumental polarization and crosstalk at the focus of the mid-infrared imaging system for the Thirty Meter Telescope

Show simple item record

dc.contributor.author Ramya, M. Anche
dc.contributor.author Packham, Chris
dc.contributor.author Anupama, G. C
dc.contributor.author Sankarasubramanian, K
dc.contributor.author Maheswar, G
dc.contributor.author Manoj, P
dc.date.accessioned 2020-11-19T13:58:16Z
dc.date.available 2020-11-19T13:58:16Z
dc.date.issued 2018-07
dc.identifier.citation Proceedings of the SPIE, Vol. 10702, pp. 1070298-1- 1070298-9 en_US
dc.identifier.issn 1996-756X
dc.identifier.uri http://prints.iiap.res.in/handle/2248/7285
dc.description Restricted Access © SPIE--The International Society for Optical Engineering https://doi.org/10.1117/12.2312558 en_US
dc.description.abstract The Thirty Meter Telescope (TMT) is a proposed future generation telescope which will be located on either Maunakea, Hawaii or La Palma in the Canary islands. A thermal-infrared (TIR) imager and spectrometer (MICHI) combined with an adaptive optics system is being investigated as a possible second-generation instrument for this telescope. MICHI has been designed to also have a polarimetry capability in both imaging and low dispersion spectroscopic modes. Using polarization ray tracing in Zemax, we have estimated the instrumental polarization (IP) and crosstalk introduced at the focus of the near- and mid-infrared imaging system. In our calculations, we find that the IP varies from 1.0-0.54% and 0.54-0.42%, whereas the polarization crosstalk varies between 25-4% and 4-0.7%, in the near and TIR regions respectively at the instrument port of MICHI. These values of IP and crosstalk may cause problems during the high absolute accuracy polarization observations. Here we present the polarization effects for the imaging system of MICHI and it impacts on the polarization observations. en_US
dc.language.iso en en_US
dc.publisher SPIE--The International Society for Optical Engineering en_US
dc.subject Instrumental polarization en_US
dc.subject Crosstalk en_US
dc.subject Thirty-Meter Telescope en_US
dc.subject MICHI en_US
dc.subject MIRAO en_US
dc.title The estimation of the instrumental polarization and crosstalk at the focus of the mid-infrared imaging system for the Thirty Meter Telescope en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account