Title: | Smear correction of highly variable, frame-transfer CCD images with application to polarimetry |
Authors: | Iglesias, F. A Feller, A Nagaraju, K |
Keywords: | CCD, charge-coupled device Image reconstruction-restoration Polarimetric imaging |
Issue Date: | 1-Jul-2015 |
Publisher: | Optical Society of America |
Citation: | Applied Optics, Vol. 54, No. 19, pp. 5970-5975 |
Abstract: | Image smear, produced by the shutterless operation of frame-transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report, we reformulate the smearing model to include specific variations of the sensor illumination. The corresponding desmearing expression and its noise properties are also presented and demonstrated in the context of fast imaging polarimetry. |
Description: | Restricted Access © Optical Society of America http://dx.doi.org/10.1364/AO.54.005970 |
URI: | http://prints.iiap.res.in/handle/2248/7053 |
ISSN: | 2155-3165 |
Appears in Collections: | IIAP Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Smear correction of highly variable, frame-transfer CCD images with application to polarimetry.pdf Restricted Access | 741.13 kB | Adobe PDF | View/Open Request a copy |