dc.description.abstractPrecision Doppler spectroscopy serves as an important tool for Radial Velocity (RV) observations of stars. High precision spectroscopy is bound by two major challenges, first being the instrument instability which is mainly caused by temperature and pressure variations and second, the limitations imposed by traditional wavelength calibration methods. In this work we report our progress on the development of a passively stabilized Fabry-Perot (FP) calibrator. We have designed and built an air-spaced etalon with 30 GHz free spectral range for accurately tracking the short-term drift of our high resolution (R = 60,000) Echelle spectrograph on Himalayan Chandra Telescope (HCT), Hanle. Instrument is built using off-the-shelf components, with the required temperature and pressure stability being achieved in initial test runs. For transporting light in and out of the vacuum system without incurring losses at fiber interconnects, we have used a simple way to insert a FC/APC connectorized fiber into the flange. We also present the results of transmission spectra of the FP taken with high resolution Fourier Transform Spectrometer.en_US
dc.language.isoenen_US
dc.publisherSPIE-The International Society for Optical Engineeringen_US
dc.subjectFabry-Perot etalonen_US
dc.subjectwavelength calibrationen_US
dc.subjecthigh resolution spectrographen_US
dc.subjectradial velocityen_US
dc.titleDevelopment of a stabilized fabry-perot based wavelength calibrator for precision doppler spectroscopyen_US
dc.typeArticleen_US
Appears in Collections:IIAP Publications

Files in This Item:
File Description SizeFormat 
Development of a stabilized FabryPerot based wavelength calibrator for precision doppler spectroscopy.pdf
  Restricted Access
Restricted Access4.87 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.