Please use this identifier to cite or link to this item:
http://hdl.handle.net/2248/6852
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Gosain, S | - |
dc.contributor.author | Sankarasubramanian, K | - |
dc.contributor.author | Venkatakrishnan, P | - |
dc.contributor.author | Bayanna, A. R | - |
dc.date.accessioned | 2020-11-11T01:20:18Z | - |
dc.date.available | 2020-11-11T01:20:18Z | - |
dc.date.issued | 2012-12 | - |
dc.identifier.citation | ASP conference series; Vol. 463, pp. 301- 306 | en_US |
dc.identifier.isbn | 978-1-58381-808-4 | - |
dc.identifier.uri | http://prints.iiap.res.in/handle/2248/6852 | - |
dc.description | open access © Astronomical Society of the Pacific http://www.aspbooks.org/a/volumes/article_details?paper_id=34849 | en_US |
dc.description.abstract | A new technique for solar imaging spectro-polarimetry is presented. Using the combination of a Shack-Hartmann (SH) and a Fabry-Pérot (FP) interferometer, high-cadence spectroscopic observations can be obtained at discrete wavelength positions simultaneously, thereby avoiding errors due to non-simultaneity of the wavelength scans. A SH mask is used to generate multiple images of the same field-of-view (FOV). These multiple images when passed through the FP in a collimated-beam arrangement are shifted in wavelength due to the angular dependence of the FP filter transmission profile. Thus, by re-imaging one obtains multiple images of the FOV which are tuned to different wavelength points across the spectral line, in a single exposure. The schematic of the setup and the laboratory simulation of such a configuration is presented. The technique has an advantage of simultaneity over conventional wavelength scanning filtergraphs and has potential for observing highly-dynamic phenomena like solar flares. Also, one can exploit the method to perform snapshot spectropolarimetry by designing a special polarization modulator. The limitation of this technique is that it downgrades the spatial resolution due to the downsampling of the pupil into smaller sub-apertures. However, for large aperture telescopes like 4 meter class telescopes (ATST) this is not a major issue and one can still work at sub-arcsec resolution, though not at the diffraction limit of the full aperture. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Astronomical Society of the Pacific | en_US |
dc.title | A New Technique for Solar Imaging Spectro-polarimetry using Shack-Hartmann and Fabry-Perot | en_US |
dc.type | Book | en_US |
Appears in Collections: | IIAP Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
A New Technique for Solar Imaging Spectro-polarimetry using Shack-Hartmann and Fabry-Pérot.pdf | 360.66 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.