Please use this identifier to cite or link to this item:
http://hdl.handle.net/2248/4731
Title: | On the performance of a dual-beam polarimeter at Kodaikanal tower telescope |
Authors: | Nagaraju, K Sankarasubramanian, K Rangarajan, K. E Ramesh, K. B Singh, J Devendran, P Hariharan |
Keywords: | Instrumentation: Polarimeter |
Issue Date: | Sep-2008 |
Publisher: | Astronomical Society of India |
Citation: | Bulletin of the Astronomical Society of India, Vol. 36, No. 2 & 3, pp. 99 – 110 |
Abstract: | Calibration and characterization of a dual-beam polarimeter installed at Kodaikanal Tower Telescope (KTT) for spectropolarimetric observations are presented in this paper. It was found that a slit width of 48 μ is optimum for the spectrograph setup at KTT and corresponding spectral resolution is 32.47 m\AA. It was demonstrated that the precision in polarization measurement can be achieved better than 0.1 % by increasing the exposure time. However, the polarimetric calibration accuracy is limited to 0.35% for Stokes Q and U parameters and 0.2% for Stokes V parameter, mainly due to the uncertainty in the retardance of the calibration retarder. A comparison of the magnetic field measurement between the Solar Optical Telescope (SOT) onboard Hinode and KTT for an active region was made and a good match was found after spatial smearing of Hinode/SOT measurements by 5.12''. |
URI: | http://hdl.handle.net/2248/4731 |
ISSN: | 0304-9523 |
Appears in Collections: | BASI Publications IIAP Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
On the performance of a dual-beam polarimeter at Kodaikanal tower telescope | 485.98 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.