Please use this identifier to cite or link to this item: http://hdl.handle.net/2248/2561
Full metadata record
DC FieldValueLanguage
dc.contributor.authorVenkatakrishnan, P-
dc.contributor.authorJain, S. K-
dc.contributor.authorSingh, J-
dc.contributor.authorRecely, F-
dc.contributor.authorLivingston, W. C-
dc.date.accessioned2008-07-01T05:38:42Z-
dc.date.available2008-07-01T05:38:42Z-
dc.date.issued1992-03-
dc.identifier.citationSolar Physics, Vol. 138, No. 1, pp. 107 - 121en
dc.identifier.issn0038-0938 (Print) 1573-093X (Online)-
dc.identifier.urihttp://hdl.handle.net/2248/2561-
dc.description.abstractThe equivalent width, line depth, line width, and Doppler shift of the He i 10830 Å line were extracted from two time series of spectra. Scatter plots of time-averaged line depth, line width, and Doppler shifts, as well as the root mean square temporal fluctuation of these quantities against the time-averaged equivalent width at a few hundred spatial locations were obtained. The statistical behaviour of these line parameters and their fluctuations was used to infer plausible reasons for the fluctuations. Examination of these results showed that the line parameter fluctuations could be caused by fluctuations in the coronal UV radiation (which could drive the spicules) or by the appearance of density inhomogeneities such as spicules within the line forming domain. In either case, the data can be interpreted as representing the initial phases of spicules.en
dc.format.extent1103787 bytes-
dc.format.mimetypeapplication/pdf-
dc.language.isoenen
dc.publisherSpringer Netherlandsen
dc.relation.urihttp://www.springerlink.com/content/j294w24761037q57/en
dc.relation.urihttp://adsabs.harvard.edu/abs/1992SoPh..138..107Ven
dc.subjectHeliumen
dc.subjectSolar spectraen
dc.subjectSpatial distributionen
dc.subjectSpiculesen
dc.subjectTemporal distributionen
dc.subjectDoppler effecten
dc.subjectSolar coronaen
dc.subjectSpectral line widthen
dc.subjectTime series analysisen
dc.subjectUltraviolet radiationen
dc.titleSpatio-temporal fluctuations in He I 10830 A line parameters - Evidence for spicule formationen
dc.typeArticleen
Appears in Collections:IIAP Publications

Files in This Item:
File Description SizeFormat 
Singh.pdf1.08 MBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.