Please use this identifier to cite or link to this item:
http://hdl.handle.net/2248/2333
Title: | The effect of aberrations on image quality - A study for the 1.2m Gurusikhar Infrared Telescope |
Authors: | Banerjee, D. P. K Bobra, A. D Subhedar, D. V |
Keywords: | Aberrations Cassegrain Focus Prime Focus |
Issue Date: | 1997 |
Publisher: | Astronomical Society of India |
Citation: | BASI, Vol. 25, No. 4, pp. 555 - 562 |
Abstract: | The achromatic aberrations, which in general affect image quality in telescopes, have been studied in context of the 1.2 m Gurusikhar Infrared Telescope. The analysis gives the magnitudes of aberrations for different fields of view at the Cassegrain and prime focus thereby indicating the optimal field diameter that may be used for observations. The range of acceptable back – focal distances have also been worked out, thereby setting constraints on the location of the focal plane in back – end instruments to be used on the GRIT. This study should be especially useful while designing instruments for the 1.2 m telescope, in planning observations or in subsequent data analysis |
URI: | http://hdl.handle.net/2248/2333 |
Appears in Collections: | BASI Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
dipankar.pdf | 535.41 kB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.