Title: | Towards absolute gain calibration of the TACTIC imaging element |
Authors: | Tickoo, A. K Dhar, V. K Venugopal, K Yadav, K. K Kaul, S. K Koul, R Kothari, M. K Goyal, H. C Chandra, P Bhatt, N Bhat, C. L |
Keywords: | PMT Detectors Absolute Gain Calibration TACTIC Telescope |
Issue Date: | 2002 |
Publisher: | Astronomical Society of India |
Citation: | BASI, Vol. 30, No. 1, pp. 381 - 384 |
Abstract: | The imaging element of the 4-element TACTIC telescope array has been in operation at Mt. Abu since 1997, for carrying out detailed investigations of gamma-ray sources in the TeV energy range. In order to characterize the progenitor particle (gamma-ray / cosmic ray), a relative gain calibration system, based on a high intensity LED, has been in operation. However, for calorimetric purposes, an absolute gain calibration system is necessary and has been developed for on-line calibration of 4 out of 349- pixels of its imaging camera, using Am241 -based light pulsers. The details of the scheme followed and the results obtained so far are presented in this paper. |
URI: | http://hdl.handle.net/2248/2460 |
Appears in Collections: | BASI Publications |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Tickoo.pdf | 393.85 kB | Adobe PDF | View/Open |